Damper Repair With Parts That Belong to Your Fireplace
Book Chimney Damper Repair
Give the address and what you are seeing. Our office phones back to agree a visit window and note the fireplace type.
What This Service Includes
In a factory-built fireplace the damper is a listed part with a specific blade, pivot and handle for that model, and a warped or seized one is replaced with the maker's part. Brick fireplaces have cast iron throat dampers that rust; we free and adjust them, or fit a top-sealing damper on the flue when the old one is beyond use. The notes say which route we took and why.
How a Prefab Damper Fails
Open the screen on most factory-built fireplaces and look up, and you will see a steel blade near the top of the box, worked by a handle, a lever, a knob or a pull chain. It is usually held open or shut by a spring or a notched catch. Those small parts are where it fails. Springs weaken and the blade drifts shut while a fire is burning, which fills the room with smoke. Catches wear and the blade will not stay closed, so the house loses heated air up the pipe on every cold night and dust and drafts come down. Rain coming down a pipe with a worn top rusts the blade and its hinge until it seizes. On gas log conversions the damper is meant to be clamped open, and we sometimes find the clamp missing. Because the damper is part of the listed fireplace, replacement parts come from that maker's list, and the model on the label plate tells us which ones.
Brick fireplaces have a heavy iron plate and frame set into the throat, and it fails in similar ways: a snapped handle, a dropped pivot pin, a warped plate or a frame that has rusted thin. Small parts can be replaced; a frame that has cracked or rusted through usually cannot be fixed in place, and the choice is between a replacement throat damper fitted into the old opening, where one can be found that fits, and a top-sealing damper that shuts against the top of the tile, opened and closed by a stainless cable anchored inside the firebox. Top mounted dampers seal well, but on a factory-built fireplace one may only be used if the fireplace maker allows it and the damper is listed for that use, which rules them out on many prefab models. We check before suggesting one.
Booking and Pricing a Damper Repair
Damper repair has no printed figure on this site. A spring and a handle on a common prefab model is a small job; a top sealing damper on a tall brick chimney is a much larger one. On the visit we work the damper, look at the blade and frame from below with a light, read the label plate on prefab units, and check the top of the chimney, since rain from above causes many damper failures. Then you get a written price for the repair that fits, and if there is a choice, such as a replacement throat damper against a top sealing damper on brick, both are set out side by side with what each does. Parts for older prefab models sometimes have to be ordered, and we tell you if that is the case.
Your message should say how the damper behaves now: frozen closed, frozen open, drifting shut during a fire, a handle that spins loose or has gone missing, or rusty drips landing on the grate after rain. Tell us whether the fireplace is metal or brick, and whether it burns wood or has gas logs. If it has gas logs and you find the damper closed, do not light the fireplace until it has been checked; gas logs vent through that opening. A damper visit is a good time to have the cap looked at too, since a missing or rusted top is often the cause. Houses in Rosemead, Arcadia and San Gabriel with more than one fireplace can have each damper checked on the same visit, and each one gets its own line in the written price.
Our Working Habits
Label Read First
Maker and model confirmed before parts are named
Listed Parts
Prefab repairs use parts approved for that unit
Figure on Paper
You approve the price before work begins
Photo Notes
Findings and finished work photographed for your file
Where we offer chimney damper repair
Our four focus cities have a page of their own for this service. Every other city on the list links to its area page.
Nothing on our list matches. Check the spelling, or open the full area list from the menu.
Other Fireplace and Chimney Services
Chimney Sweep
Brushing for clay tile and for the round metal pipe above a prefab firebox, from $415, using heads that will not score stainless.
Open serviceChimney Inspection
A Level 1 look at firebox, flue, cap and chase top, reading the unit's label plate where the fireplace is a prefab model.
Open serviceChimney Repair
Chase tops, pipe sections, caps, crowns and brick put right with parts that suit the chimney you actually own.
Open serviceFireplace Inspection
Room-side check of prefab and masonry units: panels, screen, doors, hearth extension and the clearances printed on the label.
Open serviceFireplace Repair
Refractory panels, firebox tops, screens, doors and dampers on prefab units replaced with parts listed for that exact model.
Open serviceChimney Level 2 Inspection
Video scan of the whole flue, $385, plus the attic run of prefab pipe and its firestops wherever we can reach them.
Open serviceChimney Cap Installation
Termination caps for prefab chimneys matched to the listing, and mesh hoods for brick flues, priced once we have measured. The figure follows the cap's size, its metal and the flue count.
Open serviceChimney Flashing Repair
Roof seams around chimneys renewed: step and counter flashing on brick, listed roof boots on metal pipe, lapped flashing on chases.
Open serviceChimney Masonry Repair
Brick stacks repointed, face-shed brick replaced and loose top courses relaid, with a mix chosen for the brick's age.
Open serviceChimney Rebuilds
Brick tops relaid from the roofline, or a tired masonry stack replaced by a framed chase housing listed metal pipe.
Open serviceFireplace Cleaning
Ash, soot and stains lifted from the firebox, with prefab refractory panels brushed gently so their surface stays intact.
Open serviceGas Fireplace Cleaning
Yearly upkeep for gas units: burner, pilot assembly, logs, glass and the outdoor vent end cleaned, then the flame watched.
Open serviceGas Fireplace Repair
Pilots, valves, ignition boards, remotes and fans on gas units diagnosed with a meter, then repaired with the maker's parts.
Open serviceFireplace Remodel
A new face, hearth or mantel for a prefab or brick fireplace, laid out from the clearances printed on the unit's label.
Open serviceFireplace Inserts
Gas inserts set into an existing firebox, $2,750 to $5,550 installed, where the old unit's listing allows one at all.
Open servicePellet Stove Repair
Pellet units diagnosed in order: venting first, then feed, igniter, fans and safety switches, repaired with the maker's parts.
Open serviceWood Stove Repair
Door seals, glass, baffles and firebrick in wood stoves renewed, and the connector pipe measured against listed clearances.
Open serviceGas Logs
Log sets chosen to suit the firebox and what a prefab unit's listing permits, with burner and valve fitted and leak tested.
Open serviceChimney Seismic Retrofit
Brick stacks on older houses braced, strapped or rebuilt lighter, and prefab chases checked for loosened framing after shaking.
Open serviceChimney Crown Repair
Cracked or crumbling mortar lids on brick chimneys sealed or recast, with a gap left where the flue tile meets new concrete.
Open serviceDryer Vent Cleaning
Lint cleared from the duct between dryer and outside hood, and the hood flap checked so it closes cleanly.
Open serviceChimney Liner Installation
Stainless liners for brick flues and replacement pipe for prefab chimneys, sized to the appliance that will vent through them.
Open serviceChimney Leak Repair
Water in a ceiling near a chimney traced to its source, whether a rusted chase top, cap, flashing or brick, $555 to $3,300.
Open serviceChimney Waterproofing
Repellent coating for brick or stucco chimneys that soak up rain, applied after open joints and a cracked crown are dealt with.
Open serviceChimney Chase Cover
Rusted or flat chase tops on framed chimneys replaced with custom stainless or galvanized covers that shed water.
Open service